Skip to content
Complete-line project desk · Allot Tech (Suzhou) Co., Ltd.

XGF product model reference

XGF50-50-15 Water Filling Machine — 24,000 BPH Reference

Use the verified XGF50-50-15 specification as a starting point, then confirm the bottle, product water, closure, connected equipment and complete-line acceptance basis.

Direct answer

What is the XGF50-50-15 water filling machine reference?

The XGF50-50-15 is an XGF rinsing, normal-pressure filling and capping monoblock with a published reference output of 24,000 bottles per hour for 500 ml bottles. Its station configuration is 50 rinsing / 50 filling / 15 capping positions. The catalog lists a machine size of 5,900 × 4,123 × 2,700 mm, a reference weight of 8,600 kg and installed power of 7.87 kW. These values describe the filling platform, not guaranteed saleable output for a connected production line.

Reference XGF50-50-15 XGF bottled water rinsing filling and capping platform

Reference XGF filling equipment image. Final arrangement, materials, components, guarding and options are confirmed for the actual order.

Verified catalog specification

XGF50-50-15 reference data

Reference output
24,000 BPH at 500 ml
Station configuration
50 rinsing / 50 filling / 15 capping positions
Nominal container family
500–2,000 ml
Machine dimensions
5,900 × 4,123 × 2,700 mm
Reference weight
8,600 kg
Installed power
7.87 kW

Reference qualification: these figures describe the published filling platform. Complete-line saleable output, final model configuration, current availability and commercial scope require a project-specific written quotation.

System focus 01

Where the XGF50-50-15 sits in the XGF range

This model is the first published reference above 20,000 BPH and moves the project into a larger integrated-line architecture with 50 rinsing and filling positions. Compare it directly with XGF40-40-12 and XGF60-60-15 before fixing the output class.

  • 24,000 BPH published reference at 500 ml
  • 50 rinsing / 50 filling / 15 capping positions
  • Nominal 500–2,000 ml container family reference
  • Final model selected from the actual bottle and complete-line brief

System focus 02

Confirm the 500 ml capacity basis before selection

The 24,000 BPH value is meaningful only on the catalog reference basis. A larger or less stable bottle, different neck and cap, product-water conditions or frequent format changes can alter the usable rate and the required connected equipment.

  • Approved bottle drawing and samples
  • Neck finish, cap drawing and supply method
  • Required output for every bottle size
  • Operating window, changeovers and agreed test method

System focus 03

Connect product water, bottle infeed and closures

A filling monoblock cannot sustain output when treated-water delivery, air-conveyor bottle supply or closure handling is unstable. Define these three infeed conditions around the XGF50-50-15 rather than treating them as separate purchases.

  • Treated-water quality, flow, pressure and temperature
  • Bottle infeed geometry and air-conveyor handover
  • Cap elevator, sorter and capping compatibility
  • Cleaning, hygiene and control interfaces

System focus 04

Balance labeling and packing at 24,000 BPH

Sealed bottles leaving the XGF50-50-15 need inspection, controlled conveying, useful accumulation, labeling, coding and secondary packing on the same bottle and pack basis. A filler rating alone does not define saleable line output.

  • Filler discharge and bottle inspection
  • Accumulation for expected short stops
  • Labeler rate and format-change basis
  • Bottles-per-pack conversion and packer cycle

System focus 05

Define the quotation and acceptance boundary

The final proposal should identify the exact machine configuration, materials, bought-out components, guarding, controls, change parts, documentation, services and test conditions. Reference specifications do not replace the signed technical agreement.

  • Final general arrangement and access clearances
  • Approved component and material schedule
  • Utility loads and buyer-side connection points
  • FAT, site test, training and spare-parts scope

XGF50-50-15 selection brief

Confirm three evidence sets before requesting the final XGF50-50-15 configuration.

A model name and nominal BPH are not enough to freeze the filling center or the connected line.

Container and product

Define what enters the monoblock.

  • Bottle drawing and samples
  • Neck and closure specification
  • Product-water conditions
  • Required formats and outputs

Line and factory

Define what must sustain it.

  • Bottle-supply route
  • Label and pack formats
  • Available utilities
  • Layout and access constraints

Commercial boundary

Define what the order must prove.

  • Included equipment and options
  • Change parts and initial spares
  • Documentation and services
  • Acceptance materials and method

The catalog figures are qualified references. Current configuration, availability, output and commercial scope require a project-specific written quotation.

Buyer questions

Frequently asked questions

Use these answers as a project-planning starting point. Final equipment and performance remain subject to the confirmed brief.

Does the XGF50-50-15 guarantee 24,000 saleable bottles per hour?

No. 24,000 BPH is the published filler-platform reference for 500 ml bottles. Saleable complete-line output depends on treatment, bottle supply, closure handling, utilities, downstream equipment, changeovers, rejects and the agreed measurement method.

Which bottle information is needed for the XGF50-50-15?

Provide the bottle volume, dimensioned drawing, neck finish, cap, physical samples when available, required rate for each format and the expected number of changeovers.

Can the XGF50-50-15 be quoted without a complete production line?

It can be discussed as a filling-center scope, but every quotation still needs the treated-water, bottle infeed, closure, discharge, controls and utility boundaries that connect it to the rest of the plant.

What should be compared with the XGF50-50-15 specification?

Compare it directly with XGF40-40-12 and XGF60-60-15 before fixing the output class. Compare all candidates on the same bottle, capacity, utility, component, documentation and acceptance basis rather than model name alone.

Allot Tech project desk

Confirm the XGF model and every connected-line interface.

Share the source water, bottle, target output, pack format, factory status and destination. We will use them as the basis for a project-specific configuration discussion.